HP Array Configuration Utility XE
Version 6.41.2.0
Fri Sep 19 12:53:19 CDT 2003


Description
-----------

  The HP Array Configuration Utility (ACU) is a 
  disk configuration utility for array controllers.
  
* All other product names mentioned herein may be trademarks of their 
  respective companies.

Support
-------

Supported Operating Systems

  Red Hat Enterprise Linux 2.1 (ia64)
  United Linux 1.0 (ia64) 
  
  CISS driver version 2.4.42 or later
  (cpq_cciss_xxxx-2.4.42.i386.rpm, xxxx stands for the Linux distribution)
  These drivers are available from http://www.hp.com.
  FCA2214   fibre channel HBA driver (for MSA1000 controller) 6.0.4 or later
  FCA2355   fibre channel HBA driver (for MSA1000 controller) 4.20p or later
  FCA2404DC fibre channel HBA driver (for MSA1000 controller) 4.20p or later

Supported Controllers

  Smart Array 5312 Controller
  Smart Array 5302 Controller
  Smart Array 5304 Controller
  Smart Array 532 Controller
  Smart Array 5i Controller
  Smart Array Cluster Controller
  MSA1000 Controller
  Smart Array 641 Controller
  Smart Array 642 Controller
  Smart Array 6400 Controller
  Smart Array 6400 EM Controller

Installing & Running the Array Configuration Utility
--------------------------------------------------------------

  Installation:
    ACU is distributed using Red Hat Package Manager (RPM) packages. 
    If there is an older version of ACU (or ACU-XE) installed on the system, 
	please use "rpm -e cpqacuxe" to remove it first. Use "rpm -i <file name>" 
	to install the service.
    Note: for SuSE UnitedLinux on ia64 architectures, the "--nodeps" option
    is required to install the RPM package.
    Please type "man rpm" for other details regarding RPM.
    The software resides in /opt/compaq/cpqacuxe and the executable 
    name is cpqacuxe which is located in /usr/sbin.
    The password resetting utility is hphmmopasswd that is located in
    /opt/compaq/cpqacuxe/bld.

  Run ACU:
    
    Only scripting functions are supported. Please use cpqacuxe --help for supported options.

Known Problems

----------------

   1. The PCI slot infomation is not accurate for controllers.
   2. For SuSE UnitedLinux 1.0 for ia64 architectures, the RPM dependencies are 
      incorrect, and so the rpm must be installed with the "--nodeps" option.

Feedback
--------

  For support for ACU or Smart Array controllers, please send email to 
    support@hp.com.
  For feedback or suggestions on ACU, please send comments to acu@hp.com;
    however, we regret support cannot be provided  through this address.