<?xml version="1.0" encoding="UTF-8"?>

<cpq_package version="2.0.0.0">
  <filename>hprsm-6.30.0-9.Redhat7_3.i386.rpm</filename>
  <divisions>
    <division key="6">
      <division_xlate lang="en">Server</division_xlate>
      <division_xlate lang="fr">Server</division_xlate>
      <division_xlate lang="de">Server</division_xlate>
      <division_xlate lang="it">Server</division_xlate>
      <division_xlate lang="ja">Server</division_xlate>
      <division_xlate lang="es">Server</division_xlate>
    </division>
  </divisions>
  <operating_systems>
    <operating_system key="86">
      <operating_system_xlate>Red Hat Linux 7.3</operating_system_xlate>
    </operating_system>
  </operating_systems>
  <category key="19">
    <category_xlate lang="en">Management Agents</category_xlate>
    <category_xlate lang="fr">Agents de supervision</category_xlate>
    <category_xlate lang="de">Management-Agenten</category_xlate>
    <category_xlate lang="it">Management Agents</category_xlate>
    <category_xlate lang="ja">管理エージェント</category_xlate>
    <category_xlate lang="es">Management Agents</category_xlate>
  </category>
  <families>
    <family key="501">
      <family_xlate>ProLiant BL20p</family_xlate>
      <models>
	<model key="4928" system_id="">
	  <model_xlate>G2 (2.8GHz+)</model_xlate>
	</model>
      </models>
    </family>
    <family key="228">
      <family_xlate>ProLiant DL580</family_xlate>
      <models>
	<model key="4081" system_id="">
	  <model_xlate>G2 (1400MHz+)</model_xlate>
	</model>
	<model key="1121" system_id="">
	  <model_xlate>(700-900MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="538">
      <family_xlate>ProLiant DL560</family_xlate>
      <models>
	<model key="4765" system_id="">
	  <model_xlate>(1.5GHz+)</model_xlate>
	</model>
      </models>
    </family>
    <family key="229">
      <family_xlate>ProLiant DL380</family_xlate>
      <models>
	<model key="4706" system_id="">
	  <model_xlate>G3 (2.4GHz+)</model_xlate>
	</model>
	<model key="1342" system_id="">
	  <model_xlate>G2 (1133-1400MHz)</model_xlate>
	</model>
	<model key="1122" system_id="">
	  <model_xlate>(667-1000MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="230">
      <family_xlate>ProLiant DL360</family_xlate>
      <models>
	<model key="4764" system_id="">
	  <model_xlate>G3 (2.4GHz+)</model_xlate>
	</model>
	<model key="2543" system_id="">
	  <model_xlate>G2 (1.4GHz)</model_xlate>
	</model>
	<model key="1123" system_id="">
	  <model_xlate>(550-1266MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="269">
      <family_xlate>ProLiant DL320</family_xlate>
      <models>
	<model key="1234" system_id="">
	  <model_xlate>(800-1.53GHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="223">
      <family_xlate>ProLiant ML570</family_xlate>
      <models>
	<model key="3990" system_id="">
	  <model_xlate>G2 (1.4GHz+)</model_xlate>
	</model>
	<model key="1116" system_id="">
	  <model_xlate>(667-1000MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="224">
      <family_xlate>ProLiant ML530</family_xlate>
      <models>
	<model key="3991" system_id="">
	  <model_xlate>G2 (2.4GHz+)</model_xlate>
	</model>
	<model key="1117" system_id="">
	  <model_xlate>(667-1000MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="226">
      <family_xlate>ProLiant ML370</family_xlate>
      <models>
	<model key="4307" system_id="">
	  <model_xlate>G3 (2.4GHz+)</model_xlate>
	</model>
	<model key="1341" system_id="">
	  <model_xlate>G2 (1133-1400MHz)</model_xlate>
	</model>
	<model key="1119" system_id="">
	  <model_xlate>(667-1000MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="227">
      <family_xlate>ProLiant ML350</family_xlate>
      <models>
	<model key="4678" system_id="">
	  <model_xlate>G3 (2.0GHz+)</model_xlate>
	</model>
	<model key="2588" system_id="">
	  <model_xlate>G2 (1133-1400MHz )</model_xlate>
	</model>
	<model key="1120" system_id="">
	  <model_xlate>(667-1000MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="313">
      <family_xlate>ProLiant ML330e</family_xlate>
      <models>
	<model key="1320" system_id="">
	  <model_xlate>All Models</model_xlate>
	</model>
      </models>
    </family>
    <family key="225">
      <family_xlate>ProLiant ML330</family_xlate>
      <models>
	<model key="1349" system_id="">
	  <model_xlate>G2 (1000MHz)</model_xlate>
	</model>
	<model key="1118" system_id="">
	  <model_xlate>(667-999MHz)</model_xlate>
	</model>
      </models>
    </family>
    <family key="537">
      <family_xlate>ProLiant ML310</family_xlate>
      <models>
	<model key="4763" system_id="">
	  <model_xlate>All Models</model_xlate>
	</model>
      </models>
    </family>
  </families>
  <id product="7150" version="17244" package="100058" doc_ver="1" />
  <name>
    <name_xlate lang="en">hp Lights-Out Drivers and Agents for Red Hat Linux 7.3</name_xlate>
    <name_xlate lang="fr">Drivers et agents hp Lights-Out pour Red Hat Linux 7.3</name_xlate>
    <name_xlate lang="de">HP Lights-Out Treiber und Agents für Red Hat Linux 7.3</name_xlate>
    <name_xlate lang="it">hp Lights-Out Drivers and Agents for Red Hat Linux 7.3</name_xlate>
    <name_xlate lang="ja">hp Lights-Out ドライバおよびエージェント for Red Hat Linux 7.3</name_xlate>
    <name_xlate lang="es">Controladores Lights-Out y Agentes de hp para Red Hat Linux 7.3</name_xlate>
  </name>
  <alt_name>
    <alt_name_xlate lang="en">hp Lights-Out Drivers and Agents for Red Hat Linux 7.3</alt_name_xlate>
    <alt_name_xlate lang="fr">Drivers et agents hp Lights-Out pour Red Hat Linux 7.3</alt_name_xlate>
    <alt_name_xlate lang="de">HP Lights-Out Treiber und Agents für Red Hat Linux 7.3</alt_name_xlate>
    <alt_name_xlate lang="it">hp Lights-Out Drivers and Agents for Red Hat Linux 7.3</alt_name_xlate>
    <alt_name_xlate lang="ja">hp Lights-Out ドライバおよびエージェント for Red Hat Linux 7.3</alt_name_xlate>
    <alt_name_xlate lang="es">Controladores Lights-Out y Agentes de hp para Red Hat Linux 7.3</alt_name_xlate>
  </alt_name>
  <version value="6.30.0-9" revision="" type_of_change="0" />
  <languages>
    <languages_xlate lang="en">English (US)</languages_xlate>
    <languages_xlate lang="fr">Anglais (US)</languages_xlate>
    <languages_xlate lang="de">Englisch (US)</languages_xlate>
    <languages_xlate lang="it">English (US)</languages_xlate>
    <languages_xlate lang="ja">英語</languages_xlate>
    <languages_xlate lang="es">Inglés (EEUU)</languages_xlate>
  </languages>
  <release_date year="2003" month="4" day="1" hour="0" minute="0" second="0" />
  <description>
    <description_xlate lang="en">
      <![CDATA[This RPM is used to provide Lights-Out management capabilities for Red Hat Linux 7.3 installed on supported server systems.]]>
    </description_xlate>
    <description_xlate lang="fr">
      <![CDATA[Ce RPM permet de fournir des fonctions de supervision Lights-Out pour Red Hat Linux 7.3 sur les systèmes pris en charge.]]>
    </description_xlate>
    <description_xlate lang="de">
      <![CDATA[Dieser RPM stellt die Lights-Out Management-Funktionalität für Red Hat Linux 7.3 auf unterstützten Serversystemen bereit.]]>
    </description_xlate>
    <description_xlate lang="it">
      <![CDATA[Questo RPM viene utilizzato per consentire la gestione di Lights-Out per Red Hat Linux 7.3 installato su sistemi server supportati.]]>
    </description_xlate>
    <description_xlate lang="ja">
      <![CDATA[このRPMは、サポートされるサーバにインストールされたRed Hat Linux 7.3のためのLights-Out管理機能を提供するために使用されます。]]>
    </description_xlate>
    <description_xlate lang="es">
      <![CDATA[Este RPM se utiliza para proporcionar capacidades de gestión Lights-Out para Red Hat Linux 7.3 instalado en sistemas de servidores compatibles.]]>
    </description_xlate>
  </description>
  <prerequisite_notes>
    <prerequisite_notes_xlate lang="en">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/16806.html>hp Server Management Drivers and Agents for Red Hat Linux 7.3</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="fr">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/16806.html>hp Server Management Drivers and Agents for Red Hat Linux 7.3</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="de">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/16806.html>hp Server Management Drivers and Agents for Red Hat Linux 7.3</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="it">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/16806.html>hp Server Management Drivers and Agents for Red Hat Linux 7.3</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="ja">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/16806.html>hp Server Management Drivers and Agents for Red Hat Linux 7.3</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="es">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/16806.html>hp Server Management Drivers and Agents for Red Hat Linux 7.3</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
  </prerequisite_notes>
  <installation_notes>
    <installation_notes_xlate lang="en">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To install the package, type: 

rpm -ivh hprsm-&ltversion&gt.Redhat7_3.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  For Red Hat Linux 7.3, the HP provided SNMP stack is required for the management agents to be enabled.  This component is available here: <a href="http://www.compaq.com/support/files/server/us/locate/6323.html">http://www.compaq.com/support/files/server/us/locate/6323.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-&ltversion&gt.Redhat7_3.i386.rpm) = a50a22ea5383781af708ded6a213f98f

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="fr">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To install the package, type: 

rpm -ivh hprsm-&ltversion&gt.Redhat7_3.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  For Red Hat Linux 7.3, the HP provided SNMP stack is required for the management agents to be enabled.  This component is available here: <a href="http://www.compaq.com/support/files/server/us/locate/6323.html">http://www.compaq.com/support/files/server/us/locate/6323.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-&ltversion&gt.Redhat7_3.i386.rpm) = a50a22ea5383781af708ded6a213f98f

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="de">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To install the package, type: 

rpm -ivh hprsm-&ltversion&gt.Redhat7_3.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  For Red Hat Linux 7.3, the HP provided SNMP stack is required for the management agents to be enabled.  This component is available here: <a href="http://www.compaq.com/support/files/server/us/locate/6323.html">http://www.compaq.com/support/files/server/us/locate/6323.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-&ltversion&gt.Redhat7_3.i386.rpm) = a50a22ea5383781af708ded6a213f98f

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="it">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To install the package, type: 

rpm -ivh hprsm-&ltversion&gt.Redhat7_3.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  For Red Hat Linux 7.3, the HP provided SNMP stack is required for the management agents to be enabled.  This component is available here: <a href="http://www.compaq.com/support/files/server/us/locate/6323.html">http://www.compaq.com/support/files/server/us/locate/6323.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-&ltversion&gt.Redhat7_3.i386.rpm) = a50a22ea5383781af708ded6a213f98f

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="ja">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To install the package, type: 

rpm -ivh hprsm-&ltversion&gt.Redhat7_3.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  For Red Hat Linux 7.3, the HP provided SNMP stack is required for the management agents to be enabled.  This component is available here: <a href="http://www.compaq.com/support/files/server/us/locate/6323.html">http://www.compaq.com/support/files/server/us/locate/6323.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-&ltversion&gt.Redhat7_3.i386.rpm) = a50a22ea5383781af708ded6a213f98f

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="es">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To install the package, type: 

rpm -ivh hprsm-&ltversion&gt.Redhat7_3.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. ]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  For Red Hat Linux 7.3, the HP provided SNMP stack is required for the management agents to be enabled.  This component is available here: <a href="http://www.compaq.com/support/files/server/us/locate/6323.html">http://www.compaq.com/support/files/server/us/locate/6323.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.]]>
      </installation_notes_xlate_part>
      <installation_notes_xlate_part>
	<![CDATA[<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-&ltversion&gt.Redhat7_3.i386.rpm) = a50a22ea5383781af708ded6a213f98f

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
  </installation_notes>
  <availability_notes />
  <documentation_notes />
  <revision_history>
    <revision>
      <version value="6.30.0-9" revision="" type_of_change="0" />
      <revision_enhancements_xlate lang="en">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="fr">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="de">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="it">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="ja">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="es">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
    </revision>
    <revision>
      <version value="6.20.0-13" revision="" type_of_change="0" />
      <revision_enhancements_xlate lang="en">
	<revision_enhancements_xlate_part>
	  <![CDATA[The hp Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>]]>
	</revision_enhancements_xlate_part>
	<revision_enhancements_xlate_part>
	  <![CDATA[The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present. ]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="fr">
	<revision_enhancements_xlate_part>
	  <![CDATA[The hp Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>]]>
	</revision_enhancements_xlate_part>
	<revision_enhancements_xlate_part>
	  <![CDATA[The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present. ]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="de">
	<revision_enhancements_xlate_part>
	  <![CDATA[The hp Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>]]>
	</revision_enhancements_xlate_part>
	<revision_enhancements_xlate_part>
	  <![CDATA[The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present. ]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="it">
	<revision_enhancements_xlate_part>
	  <![CDATA[The hp Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>]]>
	</revision_enhancements_xlate_part>
	<revision_enhancements_xlate_part>
	  <![CDATA[The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present. ]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="ja">
	<revision_enhancements_xlate_part>
	  <![CDATA[The hp Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>]]>
	</revision_enhancements_xlate_part>
	<revision_enhancements_xlate_part>
	  <![CDATA[The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present. ]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="es">
	<revision_enhancements_xlate_part>
	  <![CDATA[The hp Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>]]>
	</revision_enhancements_xlate_part>
	<revision_enhancements_xlate_part>
	  <![CDATA[The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present. ]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
    </revision>
  </revision_history>
  <sw_keys>
    <sw_keys_and>
      <sw_key name="hprsm" version="0" />
      <sw_key_expectedpath></sw_key_expectedpath>
    </sw_keys_and>
  </sw_keys>
  <versioncompare />
  <superceded_packages />
  <prerequisites>
    <supported_operating_systems>
      <supported_operating_system platform="Red Hat Linux" major="7" minor="3" sr="OEM" />
    </supported_operating_systems>
    <supported_devices>
      <supported_devices_and>
	<supported_device type="PCI">
	  <supported_device_data name="ven">0E11</supported_device_data>
	  <supported_device_data name="dev">B204</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">B206</supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="PCI">
	  <supported_device_data name="ven">0E11</supported_device_data>
	  <supported_device_data name="dev">005A</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">00B2</supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="PCI">
	  <supported_device_data name="ven">0E11</supported_device_data>
	  <supported_device_data name="dev">00B1</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">00B3</supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="PCI">
	  <supported_device_data name="ven">8086</supported_device_data>
	  <supported_device_data name="dev">0960</supported_device_data>
	  <supported_device_data name="subven"></supported_device_data>
	  <supported_device_data name="subdev"></supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="PCI">
	  <supported_device_data name="ven">8086</supported_device_data>
	  <supported_device_data name="dev">1960</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">C000</supported_device_data>
	</supported_device>
      </supported_devices_and>
    </supported_devices>
    <required_diskspace size_kb="750" />
  </prerequisites>
  <installation>
    <install>
      <install_caps silent="no" needuseracct="no" />
      <command>rpm -ivh hprsm-6.30.0-9.Redhat7_3.i386.rpm</command>
      <command_params></command_params>
      <reboot_required value="no" />
    </install>
    <uninstall>
      <uninstall_caps silent="no" needuseracct="no" />
      <command></command>
      <command_params></command_params>
      <reboot_required value="no" />
    </uninstall>
  </installation>
  <platform_specific>
    <LINUX>
      <Red_Hat_Linux_7.3>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.18-3" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="lsmod" />
        </postrequisites>
      </Red_Hat_Linux_7.3>
      <Red_Hat_Linux_8.0>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.18-14" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="lsmod" />
        </postrequisites>
      </Red_Hat_Linux_8.0>
      <Red_Hat_Linux_9>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.18-19" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="lsmod" />
        </postrequisites>
      </Red_Hat_Linux_9>
      <Red_Hat_Linux_Advanced_Server_2.1>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.9-e.3" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="lsmod" />
        </postrequisites>
      </Red_Hat_Linux_Advanced_Server_2.1>
      <SuSE_SLES-7_7.2>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.4-4GB" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="lsmod" />
        </postrequisites>
      </SuSE_SLES-7_7.2>
      <UnitedLinux_1.0>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.18-4GB" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="lsmod" />
        </postrequisites>
      </UnitedLinux_1.0>
    </LINUX>
  </platform_specific>
</cpq_package>

