<?xml version="1.0" encoding="UTF-8"?>

<cpq_package version="2.0.1.0">
  <filename>hprsm-6.40.0-16.SLES7.i386.rpm</filename>
  <divisions>
    <division key="6">
      <division_xlate lang="en">Server</division_xlate>
      <division_xlate lang="ja">Server</division_xlate>
    </division>
  </divisions>
  <operating_systems>
    <operating_system key="72">
      <operating_system_xlate>SuSE Linux Enterprise Server 7</operating_system_xlate>
    </operating_system>
  </operating_systems>
  <category key="11300213">
    <category_xlate lang="en">Driver - Lights-Out Management</category_xlate>
    <category_xlate lang="ja">ドライバ - Lights-Out 管理</category_xlate>
  </category>
  <id product="7180" version="17798" />
  <name>
    <name_xlate lang="en">hp Lights-Out Drivers and Agents for SuSE Linux Enterprise Server 7</name_xlate>
    <name_xlate lang="ja">hp Lights-Out ドライバおよびエージェント for SuSE Linux Enterprise Server 7</name_xlate>
  </name>
  <alt_name>
    <alt_name_xlate lang="en">hp Lights-Out Drivers and Agents for SuSE Linux Enterprise Server 7</alt_name_xlate>
    <alt_name_xlate lang="ja">hp Lights-Out ドライバおよびエージェント for SuSE Linux Enterprise Server 7</alt_name_xlate>
  </alt_name>
  <version value="6.40.0-16" revision="" type_of_change="0" />
  <manufacturer_name>
    <manufacturer_name_xlate lang="en">Hewlett-Packard Company</manufacturer_name_xlate>
  </manufacturer_name>
  <languages langlist="en">
    <languages_xlate lang="en">English (US)</languages_xlate>
    <languages_xlate lang="ja">英語</languages_xlate>
  </languages>
  <release_date year="2003" month="7" day="3" hour="0" minute="0" second="0" />
  <description>
    <description_xlate lang="en">
      <![CDATA[This RPM is used to provide Lights-Out management capabilities for SuSE Linux Enterprise Server 7 installed on supported server systems.]]>
    </description_xlate>
    <description_xlate lang="ja">
      <![CDATA[このRPMは、サポートされるサーバ システムにインストールされたSuSE Linux Enterprise Server 7のためのLights-Out管理機能を提供するために使用されます。]]>
    </description_xlate>
  </description>
  <prerequisite_notes>
    <prerequisite_notes_xlate lang="en">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/17178.html>hp Server Management Drivers and Agents for SuSE Linux Enterprise Server 7</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="ja">
      <prerequisite_notes_xlate_part>
	<![CDATA[<a href=http://www.compaq.com/support/files/server/us/download/17178.html>hp Server Management Drivers and Agents for SuSE Linux Enterprise Server 7</a>]]>
      </prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
  </prerequisite_notes>
  <installation_notes>
    <installation_notes_xlate lang="en">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.  
 
If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  

To install the package, type: 

rpm -ivh hprsm-[version].SLES7.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.
 
To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. 

<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)

<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru

<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  In this case, either install the SNMP stack delivered on the OS media or download the SNMP stack available on <a href="http://www.compaq.com/support/files/server/us/locate/6185.html">http://www.compaq.com/support/files/server/us/locate/6185.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.

<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-[version].SLES7.i386.rpm) = f3b15984eae714435e6d6bd168601b7b

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="ja">
      <installation_notes_xlate_part>
	<![CDATA[Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.  
 
If a previous version of the Remote Insight Driver, iLO Management Interface Driver, Rack Infrastructure Interface Server, or Insight Management agents have been installed, they must be removed before this package can be installed. To remove the previous version and any packages dependent on it, type the following, in order: 

rpm -e cmanic 
rpm -e cmastor 
rpm -e cmasvr 
rpm -e cmafdtn 
rpm -e cpqrid 
rpm -e cpqhealth  

To install the package, type: 

rpm -ivh hprsm-[version].SLES7.i386.rpm 

The drivers and agents will be inserted immediately.  The Storage Agents and NIC Agents must be downloaded and installed separately.
 
To check whether the package is loaded properly, type: 

/etc/init.d/hprsm status 

You should see entries for the following:
cpqrid - Remote Insight Driver (if a Remote Insight Lights-Out Edition Card is present)
cpqci - iLO Management Interface Driver (if an iLO Management Card is present)
cpqriis - Rack Infrastructure Interface Server (if the server is a BL p-Class server blade)
cmasm2d - Remote Insight Board Agent
cmarackd - Rack Agent

If you attempt to install the RPM on an unsupported system, you will get an error message. The driver will not be operational and it is advisable to uninstall the driver at your earliest convenience. 

<b>Running the Remote Insight Driver or the iLO Management Interface Driver: </b>

Once installed, the appropriate driver will be automatically loaded every time the server boots. 

Additional information and help is available by typing either of the following: 

man cpqrid (Remote Insight Driver)
man cpqci (iLO Management Interface Driver)

<b>Running the Rack Infrastructure Interface Service</b>

Once installed, the Rack Infrastructure Interface Service will be automatically loaded every time the server boots.  

Additional information and help is available by typing:

man cpqriis

The Rack Upgrade Utility is packaged with the Rack Infrastructure Interface Service.  It allows the user to upgrade the Server Blade and Power Management Module Firmware on ProLiant BL p-Class systems.  This firmware is available here: <a href = "http://www.compaq.com/support/files/server/us/locate/6614.html">http://www.compaq.com/support/files/server/us/locate/6614.html</a>.  More information is available by typing:

man cpqblru

<b>Running the agents:</b>

The agents require the HP Server Management Drivers and Agents to be present.  They also require an SNMP stack to be available.  If SNMP support is not installed on the system, the agents will not load.  In this case, either install the SNMP stack delivered on the OS media or download the SNMP stack available on <a href="http://www.compaq.com/support/files/server/us/locate/6185.html">http://www.compaq.com/support/files/server/us/locate/6185.html</a>.  If the agents are not loaded, the Remote Insight Driver, iLO Management Interface Driver, and Rack Infrastructure Interface Service will still function normally.

<b>Previous versions of the drivers and agents</b>
Previous versions of the drivers and agents are available on <a href="ftp://ftp.compaq.com">ftp.compaq.com</a>.  To ensure the latest technology and bug fixes, HP recommends the use of this package over previous versions of the driver and agents.

MD5 CHECKSUM:
MD5 (hprsm-[version].SLES7.i386.rpm) = f3b15984eae714435e6d6bd168601b7b

Additional information about features, installation, use, and troubleshooting the HP Server Management Drivers and Agents is available in the HOWTO documents available here: <a href="http://www.compaq.com/products/servers/linux/documentation.html">http://www.compaq.com/products/servers/linux/documentation.html</a>.]]>
      </installation_notes_xlate_part>
    </installation_notes_xlate>
  </installation_notes>
  <availability_notes />
  <documentation_notes />
  <revision_history>
    <revision>
      <version value="6.40.0-16" revision="" type_of_change="0" />
      <revision_enhancements_xlate lang="en">
	<revision_enhancements_xlate_part>
	  <![CDATA[Added support for new ProLiant server models.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="ja">
	<revision_enhancements_xlate_part>
	  <![CDATA[Added support for new ProLiant server models.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
    </revision>
    <revision>
      <version value="6.30.0-9" revision="" type_of_change="0" />
      <revision_enhancements_xlate lang="en">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="ja">
	<revision_enhancements_xlate_part>
	  <![CDATA[Enhanced functionality.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
    </revision>
    <revision>
      <version value="6.20.0-13" revision="" type_of_change="0" />
      <revision_enhancements_xlate lang="en">
	<revision_enhancements_xlate_part>
	  <![CDATA[The HP Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>

The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="ja">
	<revision_enhancements_xlate_part>
	  <![CDATA[The HP Lights-Out Drivers and Agents contain the following drivers and agents:
<ul><li>Remote Insight Driver</li>
<li>iLO Management Interface Driver</li>
<li>Rack Infrastructure Interface Service</li>
<li>Remote Insight Board Agent (formerly in the Server Agents package)</li>
<li>Rack Agent (formerly in the Server Agents package)</li></ul>

The drivers can be recompiled on a non-default (or errata) Linux Kernel. If you would like to install or create the RPM for a non-default kernel, you must also install the kernel sources for your compiled kernel. In addition, the development packages required for rebuilding a kernel need to be present.]]>
	</revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
    </revision>
  </revision_history>
  <sw_keys>
    <sw_keys_and>
      <sw_key name="hprsm" version="0" />
      <sw_key_expectedpath></sw_key_expectedpath>
    </sw_keys_and>
  </sw_keys>
  <prerequisites>
    <supported_operating_systems>
      <supported_operating_system platform="SuSE Linux" major="7" minor="2" sr="OEM" />
    </supported_operating_systems>
    <supported_devices>
      <supported_devices_and>
	<supported_device type="pci">
	  <supported_device_data name="ven">0E11</supported_device_data>
	  <supported_device_data name="dev">B204</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">B206</supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="pci">
	  <supported_device_data name="ven">0E11</supported_device_data>
	  <supported_device_data name="dev">005A</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">00B2</supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="pci">
	  <supported_device_data name="ven">0E11</supported_device_data>
	  <supported_device_data name="dev">00B1</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">00B3</supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="pci">
	  <supported_device_data name="ven">8086</supported_device_data>
	  <supported_device_data name="dev">0960</supported_device_data>
	  <supported_device_data name="subven"></supported_device_data>
	  <supported_device_data name="subdev"></supported_device_data>
	</supported_device>
      </supported_devices_and>
      <supported_devices_and>
	<supported_device type="pci">
	  <supported_device_data name="ven">8086</supported_device_data>
	  <supported_device_data name="dev">1960</supported_device_data>
	  <supported_device_data name="subven">0E11</supported_device_data>
	  <supported_device_data name="subdev">C000</supported_device_data>
	</supported_device>
      </supported_devices_and>
    </supported_devices>
    <required_diskspace size_kb="850" />
  </prerequisites>
  <installation>
    <install>
      <install_caps silent="no" needuseracct="no" />
      <command>rpm -ivh hprsm-6.40.0-16.SLES7.i386.rpm</command>
      <command_params></command_params>
      <reboot_required value="no" />
    </install>
    <uninstall>
      <uninstall_caps silent="no" />
      <command></command>
      <command_params></command_params>
      <reboot_required value="no" />
    </uninstall>
  </installation>
  <platform_specific>
    <LINUX>
      <Red_Hat_Linux_7.3>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.18-3" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="/sbin/lsmod" />
        </postrequisites>
      </Red_Hat_Linux_7.3>
      <Red_Hat_Linux_8.0>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.18-14" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="/sbin/lsmod" />
        </postrequisites>
      </Red_Hat_Linux_8.0>
      <Red_Hat_Linux_Advanced_Server_2.1>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.9-e.3" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="/sbin/lsmod" />
        </postrequisites>
      </Red_Hat_Linux_Advanced_Server_2.1>
      <Red_Hat_Enterprise_Linux_2.1>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.9-e.16" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="/sbin/lsmod" />
        </postrequisites>
      </Red_Hat_Enterprise_Linux_2.1>
      <SuSE_SLES-7_7.2>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.7-17" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="/sbin/lsmod" />
        </postrequisites>
      </SuSE_SLES-7_7.2>
      <UnitedLinux_1.0>
        <requires_preconfiguration value="no" />
        <requires_postconfiguration value="no" />
        <requires_precompilation value="no" />
        <requires_postcompilation value="yes" />
        <has_prerequisites value="yes" />
        <has_postrequisites value="yes" />
        <prerequisites>
          <prerequisite_data SubType="6" value="2.4.19-82" />
          <prerequisite_data SubType="7" value="2.4.99-99" />
          <prerequisite_data SubType="11" value="casmd" />
	  <prerequisite_data SubType="5" value="${KERNELSRC}" />
          <prerequisite_data SubType="2" value="rpm -e cmanic" />
          <prerequisite_data SubType="2" value="rpm -e cmastor" />
          <prerequisite_data SubType="2" value="rpm -e cmasvr" />
          <prerequisite_data SubType="2" value="rpm -e cmafdtn" />
          <prerequisite_data SubType="2" value="rpm -e cpqriis" />
          <prerequisite_data SubType="2" value="rpm -e cpqrid" />
          <prerequisite_data SubType="2" value="rpm -e cpqci" />
          <prerequisite_data SubType="2" value="rpm -e hprsm" />
          <prerequisite_data SubType="9" value="CMAFDTNSILENT|yes" />
        </prerequisites>
        <postrequisites>
          <postrequisite_data SubType="2" value="/sbin/lsmod" />
        </postrequisites>
      </UnitedLinux_1.0>
    </LINUX>
  </platform_specific>
</cpq_package>

