# This evafilter.txt file is Rev_V1.27 12/4/03 (non-CVS)                |
#									|
# The format of the EVA Event Code values used for WEBES EVA HSV	|
# filtering contained in this file is as follows:			|
#									|
# The filter number  "0xAABBCCDD" is the complete VCS Event Code.	|
# 									|
# Where:  AA = SCID							|
#	  BB = EIP_event_number						|
#	  CC = CAC							|
#	  DD = EIP_type_code						|
#									|
# They are located in, and extracted from the EIP_Common_Prefix frame 	|
# of the event log							|
#									|
# The following is a list of EVA HSV Events which are retained.		|
# That is, these Event codes are to be processed			|
#                                                                       |
# An additional feature is that the <FONT COLOR=...></FONT> tags        |
# should be recognized by supported browers with the affect of          |
# displaying the event text in the specified color in the Summary       |
# section.                                                              |
#                                                                       |
# Color Legend:                                                         |
#                                                                       |
#    red         = Significant events                                   |
#    green       = Configuration events and return to normal status     |
#                  from a previous failure                              |
#    blue        = EVA Reboot/Resync/Restart, etc.                      |
#    darkorange  = Data Availability, CA, Customer attention needed     |
#    magenta     = Drive firmware update events                         |
#    purple      = Thresholded events                                   |
#                                                                       |
#************************************************************************
#
#------------------------------------------------------------------------
#  The Storage System Services events are:
#
0x0300000a#-<FONT COLOR=red>SCS A controller can't communicate with the CBIC</FONT>
0x0301400b#-<FONT COLOR=red>SCS Disk rendered inoperable</FONT>
0x0302410a#-<FONT COLOR=red>SCS Disk won't be used because it represents "too many"</FONT>
0x03024f0b#-<FONT COLOR=red>SCS Disk won't be used because it represents "too many"</FONT>
0x0303000a#-<FONT COLOR=blue>SCS A controller has begun booting</FONT>
#
#------------------------------------------------------------------------
#  The Fault Manager (FM) events are:
#
0x04000300#-<FONT COLOR=blue>FM Termination Events (the controller reporting itself)</FONT>
0x04010300#-<FONT COLOR=blue>FM Last Gasp Termination Events (the other controller reporting)</FONT>
0x04020101#-<FONT COLOR=blue>FM Machine check while a Termination event was processed</FONT>
0x04030102#-<FONT COLOR=blue>FM Unexpected event while a Termination event was processed</FONT>
0x04060103#-<FONT COLOR=blue>FM Insufficient Event Log Packets on the Master</FONT>
0x04070103#-<FONT COLOR=blue>FM Insufficient Event Log Packets on the non-Master</FONT>
0x040c0103#-<FONT COLOR=blue>FM Invalid EIP from remote Fault Manager</FONT>
0x040e0300#-<FONT COLOR=blue>FM Last Gasp that indicates the other should terminate operation</FONT>
0x04100103#-<FONT COLOR=blue>FM Insufficient ISR Event Log Packets on the Master</FONT>
0x04110103#-<FONT COLOR=blue>FM Insufficient ISR Event Log Packets on the non-Master</FONT>
#------------------------------------------------------------------------
#  The Fibre Channel Services (FCS) events are:
#
0x06004009#-<FONT COLOR=red>FCS Exceeded SMART threshold</FONT>
#
#	0x06014a08#-<FONT COLOR=purple>FCS Fibre Channel port failed to respond</FONT>
#	0x06020009#-<FONT COLOR=purple>A drive has reported a check condition error</FONT>
#	0x06034713#-<FONT COLOR=purple>FCS Exchange timed out</FONT>
#	0x06044812#-<FONT COLOR=purple>FCS Unexpected work</FONT>
#	0x06054909#-<FONT COLOR=purple>FCS Disk or MP didn't respond</FONT>
#	0x06074709#-<FONT COLOR=purple>FCS Target Discovery Service Descriptor timed out</FONT>
#	0x06080007#-<FONT COLOR=red>FCS Excessive link errors on Fibre Channel port</FONT>
#
0x06094013#-<FONT COLOR=red>FCS Numerous SMART errors</FONT>
0x060a0013#-<FONT COLOR=purple>FCS A drive has reported numerous check condition errors</FONT>
#
#	0x060b4709#-<FONT COLOR=purple>FCS Non-data exchange has timed out</FONT>
#
0x060c0013#-<FONT COLOR=green>FCS Loop switch detected</FONT>
0x060e9613#-<FONT COLOR=red>FCS EMU Firmware update not found</FONT>
0x060f4013#-<FONT COLOR=red>FCS EMU can communicate to drive, but controller can't</FONT>
0x06108913#-<FONT COLOR=red>FCS Controller can't communicate with EMU</FONT>
0x06109b13#-<FONT COLOR=red>FCS Controller can't communicate with EMU</FONT>
0x06130013#-<FONT COLOR=green>FCS Controller to EMU communication restored</FONT>
0x06149813#-<FONT COLOR=green>FCS Too many drive enclosures</FONT>
0x06159913#-<FONT COLOR=green>FCS FC Cable is connected to the wrong FC port</FONT>
0x06169713#-<FONT COLOR=green>FCS Controller doesn't have an address on the CAN bus</FONT>
0x06174013#-<FONT COLOR=red>FCS The EMU has bypassed a drive</FONT>
0x061a4009#-<FONT COLOR=red>FCS Disk exceeded soft error threshold</FONT>
#
#	0x061c4709#-<FONT COLOR=purple>FCS Outbound frame timed out</FONT>
#	0x061d4709#-<FONT COLOR=purple>FCS Exchange to a disk finished, but is missing data</FONT>
#
0x061e4c13#-<FONT COLOR=red>FCS Controller has detected only one port on a device</FONT>
#
#	0x061f0013#-<FONT COLOR=green>FCS Drive Single Port on Fibre fixed</FONT>
#
0x06204013#-<FONT COLOR=red>FCS Unsupported device found</FONT>
0x06220004#-<FONT COLOR=magenta>FCS Unrecognized drive or firmware found by code load</FONT>
0x06224d04#-<FONT COLOR=magenta>FCS Unrecognized drive or firmware found by code load</FONT>
#
0x06254313#-<FONT COLOR=red>FCS EMU failed to assign a hard address to a drive</FONT>
0x06268913#-<FONT COLOR=red>FCS EMU failed to assign an address to a drive</FONT>
0x06270113#-<FONT COLOR=red>FCS EMU failed to assign address(s) to a drive</FONT>
0x062b4004#-<FONT COLOR=red>FCS Drive was bypassed</FONT>
#
0x06304e13#-<FONT COLOR=red>FCS All devices in an enclosure are Single Port on Fibre</FONT>
#
#	0x06310013#-<FONT COLOR=green>FCS Enclosure Single Port on Fibre fixed</FONT>
#
0x06324e13#-<FONT COLOR=red>FCS All devices on a loop are Single Port on Fibre</FONT>
#
#	0x06330013#-<FONT COLOR=green>FCS Loop Single Port on Fibre fixed</FONT>
#
0x06354d04#-<FONT COLOR=magenta>FCS Unrecognized Fibre Channel drive firmware revision</FONT>
0x06364d04#-<FONT COLOR=magenta>FCS Unsupported Fibre Channel drive firmware revision</FONT>
0x0637c404#-<FONT COLOR=magenta>FCS Newer than supported Fibre Channel drive firmware revision</FONT>
0x0638c404#-<FONT COLOR=magenta>FCS Down-rev Fibre Channel drive firmware revision</FONT>
#
0x063d9b09#-<FONT COLOR=red>FCS Enclosure on CAB bus has no Fibre Channel connection</FONT>
0x063ec513#-<FONT COLOR=red>FCS Enclosure found on Fibre Channel, but not on CAB bus</FONT>
#
#--------------------------------------------------------------------------
#  The Container Services events are:
#
0x0700b515#-<FONT COLOR=darkorange>CS Allocation of a Virtual Disk stalled; out of space</FONT>
0x0701b515#-<FONT COLOR=darkorange>CS Expansion of a Virtual Disk stalled; out of space</FONT>
0x07050015#-<FONT COLOR=green>A member management operation has finished</FONT>
#
#--------------------------------------------------------------------------
#  The Storage System Management Interface (SCMI) event are:
#
0x09020005#-<FONT COLOR=green>SCMI Volume condition changed; no action required</FONT>
0x0906bf05#-<FONT COLOR=darkorange>SCMI Volume Missing</FONT>
0x09144005#-<FONT COLOR=red>SCMI Volume Failed</FONT>
0x0914bf05#-<FONT COLOR=red>SCMI Volume Failed</FONT>
#
0x0908b405#-<FONT COLOR=darkorange>SCMI Occupancy Alarm Level threshold has been reached</FONT>
0x091c0005#-<FONT COLOR=green>SCMI Occupancy Alarm Level Normal</FONT>
#
0x090e2e05#-<FONT COLOR=red>SCMI Temperature trip point has been reached</FONT>
0x090e3605#-<FONT COLOR=red>SCMI Temperature trip point has been reached</FONT>
0x090f2e05#-<FONT COLOR=darkorange>SCMI Temperature nearing trip point</FONT>
0x09160005#-<FONT COLOR=green>SCMI Temperature returned to normal</FONT>
#
0x09130005#-<FONT COLOR=green>Voltage sensor detected voltage out-of-range</FONT>
#
0x0915b905#-<FONT COLOR=red>SCMI Controller Failed</FONT>
0x09040005#-<FONT COLOR=green>SCMI Controller Normal</FONT>
#
0x091a2f05#-<FONT COLOR=red>SCMI Battery voltage regulator is offline</FONT>
#
0x09172805#-<FONT COLOR=red>SCMI Battery #1 has been removed</FONT>
0x091f2905#-<FONT COLOR=red>SCMI Battery #2 has been removed</FONT>
0x091e0005#-<FONT COLOR=green>SCMI Battery #1 is present</FONT>
0x09200005#-<FONT COLOR=green>SCMI Battery #2 is present</FONT>
#
0x091d2205#-<FONT COLOR=red>SCMI Battery #1 has malfunctioned</FONT>
0x09222305#-<FONT COLOR=red>SCMI Battery #2 has malfunctioned</FONT>
0x09180005#-<FONT COLOR=green>SCMI Battery #1 is normal</FONT>
0x09210005#-<FONT COLOR=green>SCMI Battery #2 is normal</FONT>
#
0x09d22a05#-<FONT COLOR=red>SCMI Blower #1 has been removed</FONT>
0x09232b05#-<FONT COLOR=red>SCMI Blower #2 has been removed</FONT>
0x09110005#-<FONT COLOR=green>SCMI Blower #1 is present</FONT>
0x09240005#-<FONT COLOR=green>SCMI Blower #2 is present</FONT>
#
0x09122405#-<FONT COLOR=red>SCMI Blower #1 is too slow</FONT>
0x09252505#-<FONT COLOR=red>SCMI Blower #2 is too slow</FONT>
#
0x09262c05#-<FONT COLOR=red>SCMI Blower/Power Supply #1 has been removed or lost power</FONT>
0x09282d05#-<FONT COLOR=red>SCMI Blower/Power Supply #2 has been removed or lost power</FONT>
0x09270005#-<FONT COLOR=green>SCMI Blower/Power Supply #1 is present</FONT>
0x09290005#-<FONT COLOR=green>SCMI Blower/Power Supply #2 is present</FONT>
#
0x092a2605#-<FONT COLOR=red>SCMI Blower/Power Supply #1 is too slow</FONT>
0x092b2705#-<FONT COLOR=red>SCMI Blower/Power Supply #2 is too slow</FONT>
#
0x092c2f05#-<FONT COLOR=red>SCMI Battery hold-up time is zero hours</FONT>
0x09050005#-<FONT COLOR=green>SCMI Battery hold-up time is > 0 hours</FONT>
#
0x092dbf05#-<FONT COLOR=darkorange>SCMI Volume Resource Availability Insufficient</FONT>
0x09090005#-<FONT COLOR=green>SCMI Volume Resource Availability Sufficient</FONT>
#
#	0x09300005#-<FONT COLOR=red>SCMI Physical drive map has been updated (nofilter)</FONT>
#
0x0942500e#-<FONT COLOR=darkorange>SCMI Snapshot marked inoperative due to insufficient space</FONT>
#
#	0x0944b90e#-<FONT COLOR=blue>SCMI An HSV controller has left the Storage System (nofilter)</FONT>
#
0x0946000e#-<FONT COLOR=green>SCMI A Data Replication Group has been created</FONT>
#
#	0x0970460f#-<FONT COLOR=purple>SCMI Drive has numerous communication failures</FONT>
#
0x0978000f#-<FOND COLOR=green>SCMI A Data Replication Group has been suspended or resumed</FONT>
#
0x09c85105#-<FONT COLOR=darkorange>SCMI Logical Disk Data Availability state is Data Lost</FONT>
0x090a0005#-<FONT COLOR=green>SCMI Logical Disk Data Availability state is Normal</FONT>
#
0x09030005#-<FONT COLOR=green>SCMI Logical Disk state changed; no action required</FONT>
0x09ca5105#-<FONT COLOR=red>SCMI Logical Disk state is Failed</FONT>
0x09cc5105#-<FONT COLOR=red>SCMI Logical DIsk state is Data Lost</FONT>
0x09cb5005#-<FONT COLOR=red>SCMI Logical Disk state is Snapshot Overcommit</FONT>
#
0x091b0005#-<FONT COLOR=green>SCMI Disk Group state is Normal</FONT>
0x09c95105#-<FONT COLOR=red>SCMI Disk Group state is INOPERATIVE</FONT>
0x09ce0005#-<FONT COLOR=darkorange>SCMI Disk Group state is INOPERATIVE MARKED</FONT>
#
0x09cdc305#-<FONT COLOR=red>SCMI Fibre Channel port FAILED</FONT>
0x09070005#-<FONT COLOR=green>SCMI Fibre Channel port NORMAL</FONT>
#
0x09010005#-<FONT COLOR=green>SCMI Physical Disk Drive state is Normal</FONT>
0x09314205#-<FONT COLOR=red>SCMI Physical Disk Drive state is Degraded</FONT>
0x09324005#-<FONT COLOR=red>SCMI Physical Disk Drive state is Failed</FONT>
0x09cf4105#-<FONT COLOR=red>SCMI Physical Disk Drive state is Not Present</FONT>
#
0x093e420e#-<FONT COLOR=red>SCMI Physical Disk Drive state is Disappeared</FONT>
0x0936000e#-<FONT COLOR=green>SCMI Physical Disk Drive has been Discovered</FONT>
#
#	0x09d1b905#-<FONT COLOR=red>SCMI The HSV controller needs attention</FONT>
#	0x09d00005#-<FONT COLOR=green>SCMI The HSV controller no longer needs attention</FONT>
#
#	0x09d35105#-<FONT COLOR=red>SCMI A Virtual Disk in the DR Group is Inoperative</FONT>
#	0x09d50005#-<FONT COLOR=red>SCMI Disk is "Single Port on Fibre"</FONT>
#	0x09d60005#-<FONT COLOR=red>SCMI Temperature sensors do not agree</FONT>
#	0x09d70005#-<FONT COLOR=red>SCMI Temperature sensors can not be accessed</FONT>
#
#---------------------------------------------------------------------------
#  The Data Replication Manager (DRM) events are:
#
0x0c00000c#-<FONT COLOR=darkorange>DRM Destination Virtual Disk has completed a full copy</FONT>
0x0c015f0c#-<FONT COLOR=darkorange>DRM Source Virtual Disk transitioned to Logging</FONT>
0x0c02610c#-<FONT COLOR=darkorange>DRM Source Virtual Disk transitioned to Logging</FONT>
0x0c03000c#-<FONT COLOR=darkorange>DRM Destination Virtual Disk is Merging</FONT>
0x0c045f0c#-<FONT COLOR=darkorange>DRM The DR Group has entered Failsafe locked</FONT>
0x0c05600c#-<FONT COLOR=darkorange>DRM The DR Group has entered Failsafe locked</FONT>
0x0c06600c#-<FONT COLOR=darkorange>DRM An unrecoverable read error on the Source</FONT>
0x0c075f0c#-<FONT COLOR=darkorange>DRM A Full Copy terminated prior to completion</FONT>
0x0c08610c#-<FONT COLOR=darkorange>DRM A Full Copy terminated prior to completion</FONT>
0x0c09620c#-<FONT COLOR=darkorange>DRM A Data Replication Log has been reset due to space</FONT>
0x0c10000c#-<FONT COLOR=darkorange>DRM A Destination DR Group has been marked for a full copy</FONT>
#---------------------------------------------------------------------------
#  The Drive Enclosure Environmental Monitoring Unit (EMU) events are:
#
0x0d000111#-<FONT COLOR=red>EMU Unrecognized EMU Event</FONT>
0x0d014011#-<FONT COLOR=red>EMU Non-Fibre Channel drive or incompatible link rate</FONT>
0x0d024111#-<FONT COLOR=red>EMU Drive improperly installed or missing</FONT>
0x0d034111#-<FONT COLOR=red>EMU Drive removed; drive locking enabled on non-locking enclosure</FONT>
0x0d044211#-<FONT COLOR=red>EMU Drive operating at different loop link rate</FONT>
0x0d330911#-<FONT COLOR=red>EMU AC power has been lost</FONT>
0x0d348011#-<FONT COLOR=red>EMU Power Supply improperly installed or missing</FONT>
0x0d359a11#-<FONT COLOR=red>EMU Power Supply has failed</FONT>
0x0d478311#-<FONT COLOR=red>EMU Blower not operating properly</FONT>
0x0d4b8211#-<FONT COLOR=red>EMU Blower improperly installed or missing</FONT>
0x0d4c8411#-<FONT COLOR=red>EMU Both blowers missing</FONT>
0x0d5b8611#-<FONT COLOR=red>EMU Temperature out of range</FONT>
0x0d5f8711#-<FONT COLOR=red>EMU 2 of 3 temperature groups exceed critical</FONT>
0x0d6f8811#-<FONT COLOR=red>EMU Internal EMU Error</FONT>
0x0d728a11#-<FONT COLOR=red>EMU EMU can't collect data for the SES page</FONT>
0x0d7e8c11#-<FONT COLOR=red>EMU Invalid data read from EMU NVRAM</FONT>
0x0d7f8b11#-<FONT COLOR=red>EMU Internal EMU Error</FONT>
0x0d828e11#-<FONT COLOR=red>EMU Enclosure has no address or address is incorrect</FONT>
0x0d838911#-<FONT COLOR=red>EMU EMU hardware failure</FONT>
0x0d858f11#-<FONT COLOR=red>EMU Power Supply didn't shutdown</FONT>
0x0d8d9011#-<FONT COLOR=red>EMU Transceiver error</FONT>
0x0da18111#-<FONT COLOR=red>EMU Power Supply voltage out of range</FONT>
0x0db58111#-<FONT COLOR=red>EMU Power Supply current out of range</FONT>
0x0dd89211#-<FONT COLOR=red>EMU Enclosure invalid NVRAM read error</FONT>
0x0dd99111#-<FONT COLOR=red>EMU Enclosure backplane error</FONT>
0x0ddd9311#-<FONT COLOR=red>EMU I/O Module error</FONT>
0x0dde9511#-<FONT COLOR=red>EMU I/O Module can't communicate with EMU</FONT>
0x0dec9411#-<FONT COLOR=red>EMU I/O Module invalid NVRAM read error</FONT>
#---------------------------------------------------------------------------
#   The Host Port (HP) event is:
#
#	0x42000006#-Host Port Fibre Channel link is down
#	0x42000008#-Host Port Fibre Channel link is down
#	0x42010006#-Host Port Fibre Channel link failed
#	0x42010008#-Host Port Fibre Channel link failed
#	0x42030007#-Host Port Fibre Channel link has excessive errors
#	0x42044a08#-<FONT COLOR=red>Host Port Fibre Channel port failed to respond</FONT>
#
#---------------------------------------------------------------------------
#   The Diagnostic Operations Generator (DOG) event is:
#
0x83002014#-<FONT COLOR=red>Diag On-board diagnostic failed</FONT>
0x83013014#-<FONT COLOR=red>Diag GBIC SSF Serial ID Data check code failure</FONT>
0x83022214#-<FONT COLOR=red>Diag Battery assembly failure: Battery #1</FONT>
0x83032314#-<FONT COLOR=red>Diag Battery assembly failure: Battery #2</FONT>
0x83043114#-<FONT COLOR=red>Diag Battery assembly IIC operation failure: Battery #1</FONT>
0x83053214#-<FONT COLOR=red>Diag Battery assembly IIC operation failure: Battery #2</FONT>
0x83063314#-<FONT COLOR=red>Diag Soft cache memory ECC error or low battery voltage</FONT>