OSMKPEN - SYS1059 ERROR MESSAGE WHEN USING PEN FOR OS/2 WARP 10/20/94 ================================================================ SYS1059 ERROR MESSAGE WHEN USING PEN FOR OS/2 WARP ================================================================ Please Read Entire Document for Full Explanation of Procedures ---------------------------------------------------------------- SYMPTOM: Receiving a SYS1059 Error Message. RESOLUTION: The system cannot run the specified program. You must apply a fix to the Pen installation program. PROCEDURE: 1. Install the PATCH utilities: A. Select OS/2 System. B. Select System Setup. C. Select Selective Install. D. Select OK on the System Configuration window. E. Select Serviceability and Diagnostics Aids. F. Select Install from the OS/2 Setup and Installation window and follow the instructions on the screen. 2. There are two methods for applying the fix for the Pen for OS/2 installation program. Select the method for your situation. Method 1: Reinstalling Pen for OS/2: 1. Copy the PEN.DAT file that is located in the \DISK10 directory where Pen for OS/2 installed. 2. Change to the drive and directory where Pen for OS/2 installed. At an OS/2 command prompt, type: PATCH PEN.DAT /A and press Enter. 3. Install Pen for OS/2. Method 2: Installing Pen for OS/2 for the first time: 1. Copy the PEN.DAT file that is located in the \DISK10 directory on the OS/2 CD-ROM, to the Pen for OS/2 Diskette 1. 2. Insert the Pen for OS/2 Diskette 1 into drive A. 3. From an OS/2 command prompt, go to drive A, and type: PATCH PEN.DAT /A and press Enter. NOTE: A message appears confirming that the fix is applied. 4. Install Pen for OS/2. ---------------------------------------------------------------- IBM disclaims all warranties, whether express or implied, including without limitation, warranties of fitness and merchantability with respect to the information in this document. By furnishing this document, IBM grants no licenses to any related patents or copyrights.